High pressure chillers use either air- or water-cooled condensers.

A) True
B) False

Correct Answer

verifed

verified

A benefit of operating a compressor unloaded is ____.


A) reduced energy costs
B) reduced compression ratios
C) increased cooling
D) both a and b

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

When referring to evaporators, the terms "direct expansion" and "dry type" can be used interchangeably.

A) True
B) False

Correct Answer

verifed

verified

Explain the difference, with respect to superheat, between a dry type evaporator and a flooded evaporator.

Correct Answer

verifed

verified

The dry type evaporator (direc...

View Answer

Direct expansion evaporators have ____.


A) expansion joints between sections of the evaporator
B) an established superheat at the outlet of the evaporator
C) subcooling at the outlet of the evaporator
D) an established superheat at the inlet of the evaporator

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

The pressure difference in a low-pressure chiller is produced by a(n) ____________________ compressor.

Correct Answer

verifed

verified

Thermostatic expansion valves are the only metering devices used in high pressure chillers.

A) True
B) False

Correct Answer

verifed

verified

In a lithium bromide system, the refrigerant boils at 40°F. What is the corresponding absolute pressure required?

Correct Answer

verifed

verified

0.122 lb/i...

View Answer

A chiller typically cools ____________________ (what liquid?) for the purpose of air conditioning.

Correct Answer

verifed

verified

The device that automatically helps to remove non-condensables from a chiller is called a(n) ____________________.

Correct Answer

verifed

verified

Low pressure chillers use either air- or water-cooled condensers.

A) True
B) False

Correct Answer

verifed

verified

A reciprocating compressor with six cylinders, three banks of two cylinders each, can have its capacity reduced by unloading to ____% of full capacity.


A) 12.5
B) 25
C) 33-1/3
D) 50

E) None of the above
F) A) and C)

Correct Answer

verifed

verified

The pressure difference in an absorption chiller where the source of energy is steam or hot water is produced with the use of a(n) ____________________ solution.

Correct Answer

verifed

verified

Explain how absorption refrigeration is different compression refrigeration.

Correct Answer

verifed

verified

The absorption process uses heat as the ...

View Answer

What is the reason to use cylinder unloading in high pressure chillers?

Correct Answer

verifed

verified

Provide capacity con...

View Answer